Tender brief
The supplier will engage in a service contract, focused on providing Leakage Detection in line with the Industrial Emissions Directive (IED). EA BAT guidance dictates that the scope for LDAR is sources of leakage of Volatile Organic Carbon (VOC’s) including methane. (Biological waste treatment: appropriate measures for permitted facilities - 11.
Emissions control - Guidance - GOV.UK) The following type of assets are included but not limited to the LDAR scope; · Double membrane roofs (air blower vent) · Roof and cover fixings · Pressure relief valves and vents · Feeding and digestate separation units · Gas pipes · Conveyors and presses · Compressor · Combined heat and power plant (methane slippage) · Gas upgrading plant · Reception storage · Digestate storage · Pits and sumps, for example condensate pits Testing Method The Bioresource and Energy Services team require surveys to detect fugitive emissions of Volatile Organic Compounds (VOC’s) and other substances to air including methane.
The LDAR survey methodology must fully comply with EA guidance Biological waste treatment: appropriate measures for permitted facilities (2024) Section 11.9 - Leak Detection & Repair and currently utilise the Optical Gas Imaging (OGI) hand held camera method to enable visualisation of gas leaks with quantification of emission rate and emission concentration.
Sector codes (CPV)
71900000Want to track when this comes up for re-tender?
Save this notice to your dashboard and we'll alert you when a similar opportunity is published. Or run a fit check on similar live tenders now.
Free to start · 30 seconds · no card
Already a member? Open it in your dashboard
Open the official noticeOther tenders from United Utilities Water Limited
Supply of Wastewater Sample Systems · United Utilities Water Limited
plannedPRO004672- DPS- Liming Treatment of Wastewater Sludge Services · United Utilities Water Limited
unknownPRO005084-Services-Framework-DNM Linear Monitor Installs
plannedProcurement of Dynamic Market solutions to support Process Equipment requirements across the business
openSupply of Wastewater Sample Systems
open